Authorized Channel · Bently Nevada Condition Monitoring Products & Services

Get a Quote · Tech Docs

Technical Documents

The Tech Docs library explains how Bently Nevada protection hardware is chosen, installed, configured, and troubleshot — written from the spare-parts bench, for the people who keep the machines running. Every guide is practical: part numbers, threads, connectors, and the mistakes we see most often.

New guides are added continuously. If you need the official factory datasheet for a specific model, ask with your inquiry and it travels with the quote.

  • Velomitor & Vibration Sensors Installation Notes

    These installation notes summarize the mechanical and electrical points that decide whether a Velomitor & Vibration Sensors installation performs to specification from day one. Key points at a glance Velomitor and piezo-velocity families for bearing-cap and frame measurements Standard sensitivities: 7.87 V/mm/s (200 mV/in/s) and 100 mV/g variants Mounting threads and housing options for wet…

  • 3500 Monitoring System Commissioning Checklist

    Run this checklist when a 3500 Monitoring System unit goes into a rack for the first time — it covers the checks that prevent the classic first-month callbacks. Key points at a glance 3500/42M monitors radial and axial vibration in 4 channels per module Rack configuration lives in the 3500/20 interface — spare cards restore…

  • Velomitor & Vibration Sensors Replacement & Cross-Reference

    This page maps discontinued Velomitor & Vibration Sensors part numbers to the parts we stock today, and lists what stays interchangeable and what does not. Key points at a glance Velomitor and piezo-velocity families for bearing-cap and frame measurements Standard sensitivities: 7.87 V/mm/s (200 mV/in/s) and 100 mV/g variants Mounting threads and housing options for…

  • 3300 NSv Compact Proximity Sensors Overview

    This overview explains what the 3300 XL 8 mm Proximity Probe System family does inside a Bently Nevada protection train, which models belong to it, and how its parts fit together. Key points at a glance Tip diameters: 5 mm, 8 mm standard; case lengths and threads per the installed system Gap voltage is set…

  • 3500/15 & Legacy Power Supplies Troubleshooting

    Work through this checklist before replacing a 3500/15 & Legacy Power Supplies unit — most field symptoms trace to wiring, grounding, or configuration rather than a failed module. Key points at a glance 3500/15 power input module converts cabinet power to regulated rack supply Dual and triple (TMR) power input options for redundant racks Legacy…

  • 3500/25 Keyphasor Module Installation Notes

    These installation notes summarize the mechanical and electrical points that decide whether a 3500 Monitoring System installation performs to specification from day one. Key points at a glance 3500/42M monitors radial and axial vibration in 4 channels per module Rack configuration lives in the 3500/20 interface — spare cards restore in minutes The 3500/25 keyphasor…

  • 3500 Monitoring System Configuration Basics

    This page collects the configuration points that decide how a 3500 Monitoring System unit behaves in the rack: setpoints, recording, and the interfaces it talks to. Key points at a glance 3500/42M monitors radial and axial vibration in 4 channels per module Rack configuration lives in the 3500/20 interface — spare cards restore in minutes…

  • 3300 XL Extension Cable Selection Guide

    This guide walks through the parameters you need to order the right 3300 XL Extension Cable part the first time: dimensions, environment, and the part numbers of the units it must work with. Key points at a glance Standard lengths from 0.5 m to 9 m and beyond; armored and non-armored options Cable length must…

  • 3300 XL 8 mm Proximity Probe System Selection Guide

    This guide walks through the parameters you need to order the right 3300 XL 8 mm Proximity Probe System part the first time: dimensions, environment, and the part numbers of the units it must work with. Key points at a glance Tip diameters: 5 mm, 8 mm standard; case lengths and threads per the installed…

  • Machinery Protection Configuration Guide

    A practical guide to configuring alarm and trip setpoints, voting logic, and communication channels on 3500 series systems.

Browse by product family

Keep reading

Can’t find the guide you need? Send us the model number — if it matters to your machine, it belongs in this library, and our team answers within one business day.

Ask a Question